Qualifier X-Ray’s straightforward
design couldn’t be simpler.
Step 1: Connect Hand Held Unit to Residential side of Ground Block
Step 2: Push Blue Button on Hand Held unit. Vehicle unit will transmit ingress signal which blankets house.
Step 3: Hand Held device indicates a Pass/Fail along with the Ingress Integrity measurement
- Non-Intrusive: X-Ray can accurately determine if a home has an ingress issue without ever entering the home
- Reduces Return Service Calls: X-Ray employs a superior one-time test methodology and finds intermittent problems that can be missed using traditional test methods.
- Powerful Troubleshooting Tool: X-Ray has been proven to find problematic ingress points in the network that are difficult to find
- Extremely Small and Lightweight: X-Ray is not much bigger than a typical PDA and can be conveniently be carried in a belt holder
- Simple, Quick, and Easy: X-Ray is so easy to use
- a single button push is all it takes
- Shielding Integrity Reading: Enables detection in the range of 80 dB (very good) to 25 dB (very poor).
- PASS / FAIL Function: Based on user settable thresholds.
FCC License Requirement
An FCC license is required to operate the Qualifier X-Ray System, specifically the vehicle mount transmitter device (VMD).
Refer to the Qualifier Transmitter Licensing section on at http://www.comsonics.com/downloads.html for application instructions and templates. |
SPECIFICATIONS:
|
Hand Held Device (HHD) |
|
| Operational Control |
Single Button |
|
| Input Frequency Range |
27.45 to 27.49 MHz |
|
| Input Level Range |
-30 to +30 dBmV |
|
| Integrity Measurement Range |
25 to 80 dB (shielding effectiveness) |
|
| Accuracy |
± 2.0 dB (input level to converted reading) |
|
| Threshold Function Range |
25 to 79 dB (user selectable, 80 disable) |
|
| Power Source: |
AAA Alkaline x 3 cells |
|
| Custom Display: |
Custom 1.2” x 1.5” (30 mm x 39 mm) With Backlight |
|
| Auto Power Off: |
16 Seconds |
|
| Size: |
5.5” x 2.5” x 1.75”
(140 mm x 64 mm x 44 mm) |
|
| Weight: |
0.5 lbs (0.23 kg) |
|
| Operating Temperature: |
0ºF to 120ºF (-18ºC to 49ºC) |
|
| Storage Temperature: |
-20ºF to 150ºF (-29ºC to 66ºC) |
|
| Humidity: |
0 ~ 95% non-condensing |
|
 |
|
|
| Vehicle Mounted Device (FCC license required) |
|
Output Frequency
(User Selectable): |
27.45 MHz, 27.47 MHz*, or 27.49 MHz |
|
| Output Power: |
5 Watts, EIRP |
|
| User Controls: |
Power On/Off and Test/Output Frequency |
|
| Indicators: |
Standby, Power, Receive & Transmit |
|
| Power Source: |
12 VDC Negative Ground, < 12 Watts |
|
| Size: |
6” x 3.5” x 1” (150 mm x 90 mm x 26 mm), excluding protrusions |
|
| Mounting: |
Fixed |
|
| Operating Temperature: |
0ºF to 140ºF (-18ºC to 60ºC) |
|
| Storage Temperature: |
-20ºF to 150ºF (-29ºC to 66ºC) |
|
| Humidity: |
0 – 95% Non-Condensing |
|
| |
|
| *Factory Default Setting |
| |
|
|