| Typical Distance |
10 to 2000 feet (3 to 600 meters) |
|
| Accuracy |
± 1%, ± 3ft., whichever is greater |
|
| Significant Fault |
Electrical short circuit (0 ohms) or electrical open circuit (infinite ohms) |
|
| No Fault Conditions |
> 50% and < 200% of nominal impedance |
|
| Resolution |
1 ft. (0.1 meter) |
|
| Auto Sensitivity Mode |
Normal mode for locating significant faults |
|
| Manual Sensitivity Mode |
Levels 1 through 4 allow experienced user to identify non-short circuit and non-open circuit conditions |
|
| Units of Measure |
Feet or meters (user selectable) |
|
| VOP Range |
50% to 99% in 1% increments |
|
 |
|
| Powering Specifications: |
|
| Power |
Rechargeable custom battery pack,
NiMH Charger included, Auto off |
|
 |
|
| Physical Specifications: |
|
| Display |
LCD, Custom |
|
| Back Light |
Manual on/off, timed auto off |
|
| Keypad |
Membrane |
|
| Size |
High x 3.5" wide x 2.3" deep
(195.6 x 88.9 x 58.4 mm) |
|
| Weight |
1 pound, 1 oz (.48 kg.) |
|
 |
|
| Environmental Specifications: |
|
| Operating Temperature |
0°F to 120°F (-18°C to 49°C) |
|
| Operating Humidity |
0% to 100+% - withstands total immersion into one foot of water for 30 minutes without intrusion |
|
| Storage Temperature |
-20°F to 150°F (-29°C to 66°C) |
|
| Storage Humidity |
0% to 90% (non-condensing) |
|
| |
| |