Click for Virtual Demo
FEATURES:

Favorite Channel Mode

  • Displays Five Preselected Channels
    • Analog Visual Carrier Level
    • Digital Multiplex Power
  • Slope
  • Pass/Fail Indication*

Single Channel Mode

  • Analog
    • Video & Audio Levels
    • V-A Ratio
  • Digital
    • Multiplex Power
    • 64 or 256 QAM Type*
    • Flatness
    • MER
    • Pre-FEC BER and Post-FEC BER
  • Pass/Fail Indication*

Reverse Path Analysis

  • Normal, Average, or Peak Hold Display
  • Peak Level Indicator
  • Frequency Range Zoom
  • Level Range Shift
  • Pass/Fail Indication*

X-Ray Reverse Ingress


(Requires optional X-ray transmitter)
  • Active Ingress Test Signal
  • Premise Shielding Integrity Measurement
  • Pass/Fail Indication*

Throughput Mode

  • Downstream
    • Data Speed1
    • Level
    • Frequency
    • Modulation Type
  • Upstream
    • Data Speed1
    • Level
    • Frequency
    • Rate
  • Pass/Fail Indication*
    1Provisioned Modem and Throughput
    Server Required

AutoTest

  • Function for Field Measurements and
    Internal Storage of Channel Data*
  • Unique Test Naming Feature
  • Pass/Fail Indication*
  • On Screen Display of Failed Measurements
  • Supports 30 unique Channel plans

 

 
SPECIFICATIONS:

Analog Television In accordance to procedures in NCTA Recommended Practices, Third Edition

Tuning Range 54 to 960 MHz

Signal Level Range -30 to +30 dBmV

Auto Level Display 5 dB Steps

Video Signal Level ± 2.0 dB accuracy

Audio Signal Level ± 2.0 dB accuracy

Channel Set
  • STD-EIA (Factory Default)
  • Fully Customize Channel/Frequency/Type with Companion PC Configuration Utility
  • Store Up to 30 Field Selectable Channel Sets in Unit

Favorite Channels Five Channels per Channel Set Preselected in Companion PC Configuration Utility

Digital Television In accordance to procedures in NCTA Recommended Practices, Third Edition

Power Level Range -30 to +30 dBmV

Multiplex Power Level ± 2.0 dB accuracy

Measurements Range -20 to +20 dBmV

MER ± 2.0 dB accuracy

Post-FEC BER 10-4 to 10-9

Pre-FEC BER 10-4 to 10-9

High Speed Data

Upstream Throughput Up to 3 Mbps

Downstream Throughput Up to 15 Mbps

X-Ray Reverse Ingress  

D2I Range 10 - 100 dB (D2I = Dwelling Ingress Integrity)
 

Reverse Path Analysis  

Frequency Range 5 - 42 MHz (65 MHz Europe)

Level Range -40 - +60dBmV (20 - 120 dBμv)
 

General

Size 7” X 4.5” X 1.5”

Weight 20 oz

Battery Li-Ion rechargeable, 3.7V, 4800 mAh
nominal run time ≈ 4 hours
charge time ≈ overnight

AC Charger 5 VDC, 1A, mini USB

PC Utility Interface mini USB

Operating Temperature 0ºF to 120ºF (-18ºC to 49ºC)

Storage Temperature -20ºF to 150ºF (-29ºC to 66ºC)

Humidity 0 ~ 95% non-condensing
   
 