FEATURES:
Favorite Channel Mode
- Displays Five Preselected Channels
- Analog Visual Carrier Level
- Digital Multiplex Power
- Slope
- Pass/Fail Indication*
Single Channel Mode
- Analog
- Video & Audio Levels
- V-A Ratio
- Digital
- Multiplex Power
- 64 or 256 QAM Type*
- Flatness
- MER
- Pre-FEC BER and Post-FEC BER
- Pass/Fail Indication*
Reverse Path Analysis
- Normal, Average, or Peak Hold Display
- Peak Level Indicator
- Frequency Range Zoom
- Level Range Shift
- Pass/Fail Indication*
X-Ray Reverse Ingress
(Requires optional X-ray transmitter)
- Active Ingress Test Signal
- Premise Shielding Integrity Measurement
- Pass/Fail Indication*
Throughput Mode
- Downstream
- Data Speed1
- Level
- Frequency
- Modulation Type
- Upstream
- Data Speed1
- Level
- Frequency
- Rate
- Pass/Fail Indication*
1Provisioned Modem and Throughput
Server Required
AutoTest
- Function for Field Measurements and
Internal Storage of Channel Data*
- Unique Test Naming Feature
- Pass/Fail Indication*
- On Screen Display of Failed Measurements
- Supports 30 unique Channel plans
|
| |
|
| SPECIFICATIONS: |
|
| Analog Television |
In accordance to procedures in NCTA Recommended Practices, Third Edition |
|
| Tuning Range |
54 to 960 MHz |
|
| Signal Level Range |
-30 to +30 dBmV |
|
| Auto Level Display |
5 dB Steps |
|
| Video Signal Level |
± 2.0 dB accuracy |
|
| Audio Signal Level |
± 2.0 dB accuracy |
|
| Channel Set |
- STD-EIA (Factory Default)
- Fully Customize Channel/Frequency/Type with Companion PC Configuration Utility
- Store Up to 30 Field Selectable Channel Sets in Unit
|
|
| Favorite Channels |
Five Channels per Channel Set Preselected in Companion PC Configuration Utility |
 |
|
| Digital Television |
In accordance to procedures in NCTA Recommended Practices, Third Edition |
|
| Power Level Range |
-30 to +30 dBmV |
|
| Multiplex Power Level |
± 2.0 dB accuracy |
|
| Measurements Range |
-20 to +20 dBmV |
|
| MER |
± 2.0 dB accuracy |
|
| Post-FEC BER |
10-4 to 10-9 |
|
| Pre-FEC BER |
10-4 to 10-9 |
 |
|
| High Speed Data |
 |
|
| Upstream Throughput |
Up to 3 Mbps |
|
| Downstream Throughput |
Up to 15 Mbps |
 |
|
| X-Ray Reverse Ingress |
|
|
| D2I Range |
10 - 100 dB (D2I = Dwelling Ingress Integrity) |
 |
|
|
| Reverse Path Analysis |
|
|
| Frequency Range |
5 - 42 MHz (65 MHz Europe) |
|
| Level Range |
-40 - +60dBmV (20 - 120 dBμv) |
 |
|
|
| General |
 |
|
| Size |
7” X 4.5” X 1.5” |
|
| Weight |
20 oz |
|
| Battery |
Li-Ion rechargeable, 3.7V, 4800 mAh
nominal run time ≈ 4 hours
charge time ≈ overnight |
|
| AC Charger |
5 VDC, 1A, mini USB |
|
| PC Utility Interface |
mini USB |
|
| Operating Temperature |
0ºF to 120ºF (-18ºC to 49ºC) |
|
| Storage Temperature |
-20ºF to 150ºF (-29ºC to 66ºC) |
|
| Humidity |
0 ~ 95% non-condensing |
| |
|
|
|